The INSUCHECK10000 digital insulation tester is designed for use in electrical installations where the induction field is very strong. Its high noise immunity and user-selectable digital filters make it the most robust and reliable instrument with user-selectable test voltages.

It is also used to test the electrical insulation of cables, motors, generators, transformers, etc., in power generation plants, utilities, and distribution systems.

Its advanced features, such as Bluetooth connectivity, audio feedback, and a color TFT touchscreen, make it easier to use than ever before. It can store data in its internal memory with real-time timestamps. Data can be transferred to a computer or mobile phone for further analysis. It performs tests such as Polarization Index, Dielectric Absorption Ratio, dielectric discharge, ramp diagnostic test, and step voltage test.

  • Selectable short-circuit current: 1.2 mA, 3 mA, and 6 mA
  • User-selectable digital filters
  • 8 mA noise rejection
  • Runs on a rechargeable lithium-ion battery or AC power
  • Bluetooth connectivity for data logging
  • Color TFT touchscreen
  • Audible readout
  • The test voltage can be selected in 10-V increments from 100 V to 1,000 V and in 25-V increments from 1,000 V to 1,000 V.
  • Voltage measurement
Specifications
Rated Voltage Maximum Resistance Accuracy
250 V 50 GΩ 5% ± 10D
500 GΩ 20% ± 10D
500 V 100 GΩ 5% ± 10D
1 TΩ 20% ± 10D
1000 V 200 GΩ 5% ± 10D
2 TΩ 20% ± 10D
2500 V 500 GΩ 5% ± 10D
5 TΩ 20% ± 10D
5000 V 1 TΩ 5% ± 10D
10 TΩ 20% ± 10D
10000 V 2 TΩ 5% ± 10D
20 TΩ 20% ± 10D

Test Voltage Accuracy

+7% ± 10 V

Capacitance Measurement

1 nF to 50 µF; Accuracy: ±10% + 5 nF (up to 5 kV)
1 nF to 25 µF; Accuracy: ±10% + 5 nF (above 5 kV)

Insulation Leakage Current Measurement

0.01 nA to 6 mA; Accuracy: ±5% + 0.2 nA

Protection Terminal

2% error protection, 500 kΩ leakage, 100 MΩ load

IR Test Timer Range

Time: 15 seconds to 99 minutes 59 seconds, with three programmable timers
Tests: IR(t), DAR, DD, PI, Step Voltage, Ramp Voltage

Environmental Conditions

Operating Temperature -20°C to +50°C
Storage Temperature -20°C to +70°C
Maximum Relative Humidity 90% (avoid condensation)
Altitude Protection Up to 2000 m
Ingress Protection IP67 with case closed; IP40 with case open

Applicable Standards

Standard Description
IEC 61010-1 Safety requirements for electrical equipment for measurement, control, and laboratory use
IEC 61557 Electrical safety in low-voltage distribution systems up to 1000 V AC and 1500 V DC
PART 1 General requirements
PART 2 Insulation resistance measuring equipment

Reference Conditions

Ambient Temperature +23°C ± 2 K
Relative Humidity 45%–55%
Measurement Rate 50 Hz ± 10 Hz
Line Voltage Waveform (for voltage measurements) Sinusoidal wave
Battery Voltage 14.8 V ± 1%
Operating Position Horizontal
Supply Voltage 230 V ± 15%, 50/60 Hz

Additional Error

EMC Influence (IEC 61326-1) IR: ±40D

Power Supply (Battery)

Battery 14.8 V, 7.8 Ah Li-ion
Battery Life 5.5 hours of continuous testing at 100 MΩ
Battery Charging Time 7 hours

Power Supply (AC)

Rated Input Power 230 V AC ± 15%, 50/60 Hz

Electromagnetic Compatibility (EMC)

IEC 61326-1

Immunity

IEC 61000-4-2: 8 kV air discharge, 4 kV contact discharge
IEC 61000-4-3: 3 V/m

Electrical Safety

Overvoltage Category 600 V CAT IV
Test Voltage 7.4 kV AC
Pollution Degree 2

 

  • 3 Year Limited Warranty